Home         Center of Excellence          About Us          Where to Buy          FAQ         Contact     
 www.hellausa.com     

>
Apparatus Classification

  General Information

  Classification

Ingress Protection
>
Lighting Technology

LED Technology

Hella Work Lamp Technology

Applications Engineering

Classification

Classification of Apparatus by Gas Group, Temperature Class and Gas/Vapour Type

Temperature Classes


Gas Group  Classification

450° C - T1

300°C - T2

200°C - T3

135°C - T4

100°C - T5

85°C - T6

I
for use underground in mines in the presence of Methane (fire damp)

Methane

II A
For use above ground, and subdivided according to their suitability for use in atmospheres containing specific gases and vapors as identified in the subgroups.

Ammonia

Carbon Monoxide

Chlorobenzine

Pentane

Xylene
Acetone
Ethanol
Propane
Methanol
Ethylacetate
Benzene
Amylacetate
n-Butyl Alcohol
n-Butane

Cyclohexane
Diesel
Aviation Fuel
n-Propul Alcohol

Heptane
Hexane

IIB

Coal Gas

Ethylene
Buta 1:3 Diene

Diethyl Ether

IIC

Hydrogen

Acetylene

Carbon Sulphide

*Apparatus classified in a temperature class is deemed to be suitable for use in gases and vapors appropriate to that and all lower temperature classes. For instance, a lamp reaching a temperature of 130 °C would be marked T4. That temperature would not ignite the gases or vapors in the T4 row; neither would it ignite the gases or vapors in the T3, T2 or T1 rows. However, that temperature would ignite gases or vapors in the T5 or T6 rows, such as carbon disulphide.

Classification of Apparatus Protection Type


IECEx Standard

Protection Type

Protection  Type Code

Hazard  Zone Class

Gas

Dust

 

Gas

Dust

Gas

Dust

60079-0

61241-0

General Information

60079-1

61241-1

Flameproof

EX d

Ex tD

1

20

60079-2

61241-2

Pressurized

Ex p

Ex pD

1

21

60079-5

Powder filled

Ex q

1

60079-6

Oil filled

Ex o

1

60079-7

Increased safety

Ex e

1

60079-11

61241-11

Intrinsic safety

Ex ia

Ex ib

Ex iaD

Ex ibD

0

1

20

21

60079-15

Non sparking

Energy limited

Restricted breathing

Enclosed break

Pressurized

Ex nA

Ex nL

Ex nR

Ex nC

Ex nP

2

60079-18

61241-18

Encapsulation

Ex ma

Ex mb

Ex maD

Ex mbD

0

1

20

21


Top